logo

details van de producten

Created with Pixso. Huis Created with Pixso. Producten Created with Pixso.
Testbank voor vaste meters
Created with Pixso.

High-Precision Meter Test Bench for Accurate Electric Meter Calibration

High-Precision Meter Test Bench for Accurate Electric Meter Calibration

Merknaam: GENY
Modelnummer: YC1893D
MOQ: 1 pc's
Prijs: Onderhandelbaar
Betalingsvoorwaarden: L/c, t/t, d/p
Toeleveringsvermogen: 30 pc's per maand
Detailinformatie
Plaats van herkomst:
China
Certificering:
ISO, CE
Gebruik:
Multifunctioneel energiemeter, watt-uurmeter, meter voor industrie en thuisgebruik, standaard elektr
Uitgangsspanningsbereik:
24V tot 288V
Theorie:
Elektronische Meter
Uitgangsstroombereik::
1MA tot 120A (maximaal 230a max)
Verpakking Details:
multiplexkast
Levering vermogen:
30 pc's per maand
Markeren:

electric meter calibration test bench

,

stationary meter test equipment

,

high-precision meter calibration bench

Productomschrijving

High-Precision Meter Test Bench for Accurate Electric Meter Calibration


Key Features


  • Accurate measurement of active/reactive power and energy

  • Supports start-up and no-load (creep) testing

  • Automatic marking for fast and efficient tests

  • Error analysis: basic error, average error, standard deviation, 24-hour drift

  • Tests voltage, frequency, harmonic (2nd-21st), and phase sequence effects

  • Simultaneous current testing for multiple meters on one rack

  • Non-disconnect testing for voltage and current circuits

  • Built-in protection for current open-circuit and voltage short-circuit

  • Integrated optical scanner to improve efficiency

  • Motorized and manual operation modes

  • PC software for data processing, storage, and report generation

  • Barcode input support

  • Durable mechanical design

  • Configurable from 3 to 60 meter positions


Specifications


  • Input Voltage: AC 220V ±10%, 50Hz ±2Hz

  • Operating Temperature: -10°C to +40°C

  • Operating Humidity: 35% to 95%

  • Output Voltage Range: 24V to 288V

  • Maximum Output Voltage Power: 1000VA

  • Voltage Resolution: 0.01%

  • Voltage Stability: 0.02% per 120 seconds

  • Load Variation Rate: 0.01%

  • Voltage Distortion: ≤0.3% (full linear load range)

  • Output Current Range: 1mA to 120A (up to 230A max)

  • Maximum Output Current Power: 2000VA

  • Current Resolution: 0.01%

  • Current Stability: 0.02% per 120 seconds

  • Load Variation Rate: 0.01%

  • Current Distortion: ≤0.3% (full linear load range)

  • Continuous Current: 100A

  • Phase Adjustment Range: 0° to 360°

  • Phase Resolution: 0.01°

  • Frequency Adjustment Range: 45Hz to 65Hz

  • Frequency Resolution: 0.01Hz

  • Power Output Stability: 0.02% per 120 seconds



High-Precision Meter Test Bench for Accurate Electric Meter Calibration 0


High-Precision Meter Test Bench for Accurate Electric Meter Calibration 1